40-745-731 -
Pickering Interfaces Ltd.
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
40-872-001 -
Pickering Interfaces Ltd.
The 40-872-001 is a 50 Ohm 4 to 1 RF MUX with 1 bank in a single PXI slot. It exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-872 has been minimized by careful attention to the mechanical and electrical design.
-
40-745-701 -
Pickering Interfaces Ltd.
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
40-874-001 -
Pickering Interfaces Ltd.
The 40-874-001 is a 50 Ohm 8 to 1 RF MUX with 1 bank in a single PXI slot. It has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-874 has been minimized by careful attention to the mechanical and electrical design.
-
40-872-101 -
Pickering Interfaces Ltd.
The 40-872-101 is a 50 Ohm 4 to 1 RF MUX with 1 bank in a single PXI slot. It exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-872 has been minimized by careful attention to the mechanical and electrical design.
-
40-746-751 -
Pickering Interfaces Ltd.
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
40-745-591 -
Pickering Interfaces Ltd.
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
40-745-711 -
Pickering Interfaces Ltd.
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
40-882-003 -
Pickering Interfaces Ltd.
A 50 Ohm 4 to 1 6GHz PXI RF multiplexer available as a single MUX in one PXI slot, a dual MUX in two PXI slots, or triple and quad MUXs in three slot PXI modules. This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.
-
782356-01 -
NI
40 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module—The PXI‑2796 offers a high-density, unterminated multiplexer with dual 6x1 multiplexer banks in the same module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules.
-
782357-01 -
NI
40 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2797 offers a high-density, terminated multiplexer with dual 6x1 multiplexer banks in the same module. The internal termination of the PXI‑2797 helps prevent high-power reflections that arise from open channels on the module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules.
-
778572-96 -
NI
26.5 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module—The PXI‑2596 is an RF signal multiplexer switch with dual 6x1 multiplexer banks in the same module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use the PXI‑2596 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
40-883-001 -
Pickering Interfaces Ltd.
A 50 Ohm 6GHz multiplexer available as an 8 to 1 MUX in a two slot PXI module or a 16 to 1 MUX in a three slot PXI module. It exhibits low VSWR over the full operating frequency range and consistent and flat insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making it ideal for ATE systems requiring frequent and fast operating RF switching.
-
40-882-001 -
Pickering Interfaces Ltd.
This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.
-
M9147A -
Keysight Technologies
Route signals up to 3 GHz through any of four 1 x 4 RF switch multiplexers in a single PXI module.